THC-2 Torch Height Control
Page 1-5
INSTALLATION - To Cutting Machine & Torch Lifter
UP
DOWN
DOWN
UP
MAN
AUTO
AUTO
MAN
DN
DN
UP
UP
Lifter
Motor
DC
Power
+
_
UP
115VAC
DN
115VAC
JUMPER
1TB-133
1TB-131
1TB-132
Jump to wire 106
on DC Power Supply
1PS in THC-2
Jump to wire 107
on DC Power Supply
1PS in THC-2
Add jumper and relays to THC-2
Quantity (2), 2 pole, N/O relays,
115 VAC coils - Mount in the THC-2
Double pole, single throw
toggle switch - Mount in
operator station
Figure 1-4 Typical DC Lifter Wiring